The main purpose of a current transformer is to translate the primary current in a high voltage power system to a signal level that can be handled by delicate electromechanical or electronic devices. The standard current transformer secondary winding is rated at 5a as per ansi standards. Potential transformers pts pts step down high voltages to the voltage needed by the meter usually 120v occasionally 67v. Testing of potential transformers electrical engineering info. The rating of two identical transformers operating deltadelta is 1 of the rating of three similar transformers, but connected deltadelta. The basic principle of operation of a transformer is explained in chap. Basic connection of voltage potential transformer phasephase. Easy understanding of 3phase transformer connections. Taps are provided on some transformers on the high voltage winding to. Potential transformer or voltage transformer gets used in electrical power system for stepping down the system voltage to a safe value which can be fed to low ratings meters and relays. Read through the different types we supply below and use our instrument transformer rfq form to request a specific part to meet your requirements. Brooks testingpotentialtransformers 421 needstobemeasuredwithonlymoderateaccuracy. Threephase transformers with the neutral points of the high voltage and low voltage windings connected together internally and brought out through an hoxo bushing should not be operated with the hoxo bushing ungrounded floating. Instrument transformer basic technical information and.
The burden with which the transformer is to be tested is connected across the secondary winding, and the normal primary voltage, at the. An optical voltage transformer exploits the faraday effect, rotating polarized light, in optical materials. Instrument transformers reduce the line current and voltage being provided to the. Setting procedures are only discussed in a general nature in the material to follow. Lv transformer electrical substation consists, therefore, of the set of devices dedicated to the transformation of the voltage supplied by the distribution network at medium voltage e. A threephase transformer is built for a specific connection and voltage transformation and the unit will have a nameplate with the internal connections shown. Since the meter sees 120 vac, many of the measurements it reports will be low by a factor of 35 unless they are scaled up by 35. Connections to the bottom of the meter connection block shall be made by the customer.
Each transformer is rated as 10 kva current rating is 10 a and voltage. This transformer step down the voltage to a safe limit value which can be easily measured by the ordinary low voltage instrument like a voltmeter, wattmeter and watthour meters, etc. A transformer operates on the principals of electromagnetic induction, in the form of mutual induction. The primary winding is connected directly to the power circuit either between two phases or between one phase and ground, depending on the rating of the transformer and on the requirements of the application. Ultracompact equipment specifically built for customers complex mechanical and electrical. Single phase power transformers in north america could be additive or subtractive depending on the kva and the voltage class. Y, and the first symbol indicates the connection of the primary, and the second symbol is the. The primary terminal of the potential transformer is connected to the line for measuring the line voltage. Pdf voltage transformer operation in connection with the power. Capacitor voltage transformer cvt or ccvt construction. A transformer which has only one winding per phase, part of which is common to both the primary and secondary circuits. Potential transformers pt or voltage transformers vt can be defined as devices used to step down voltage from high voltage typically used in transmission and distribution to a low voltage typically between 50150v. Bil basic impulse level is a means to express the ability of the insulation system to withstand high voltage surges.
The ratio of an instrument transformer is the relationship of its primary rating to its secondary rating. Voltage transformer or potential transformer theory. A wide variety of potential transformer connections options are available to you, such as shape, application, and connection. When a single unit or bank of three is used, there are four types of connections. The above figure shows the connection diagram of an open delta system.
The deltawye connection is the most commonly used threephase transformer connection. Key differences between current and potential transformer. Potential transformers pts or voltage transformers vts pts or vts are the most common device used. Designed to create the hv network neutral point and to limit the fault current in the phaseearth connection. The transformer connections and voltage triangles are shown in fig. The capacitor voltage transformer cvt uses a capacitance potential divider and is used at higher voltages due to a lower cost than an electromagnetic pt. Abb oem instrument transformer reference guide april 2014. Potential transformers used primarily in a step down environment to monitor voltage. Voltage regulation in transformers is the difference between. Figure 9 voltage transformer connections for ungrounded system it is of particular interest to compare figure 7b and figure 8 above. It would seem that this rating should be 23 instead of 1. Voltage transformers are in most situations connected between phase. Jun 01, 2015 potential transformer is a voltage stepdown transformer which reduces the voltage of a high voltage circuit to a lower level for the purpose of measurement.
Jefferson electric transformer while threephase devices are usually the more costeffective option, the singlephase option provides more versatility and can be attractive from a reliability and maintenance standpoint. The ratio of transformation between primary and secondary line voltage is exactly the same as that of each. In other words, for a transformer there is no direct electrical connection between the two coil windings, thereby giving it the name also of an isolation transformer. Thus we see that open delta connection, secondary line voltages form a balanced system and balanced three phase load can be supplied. A schematic drawing of a singlephase distribution transformer appears in fig. High voltage connections are made with elbow cable connectors to bushing inserts installed in wells shown on top of the transformer. Actually they are protective type voltage transformer. Electrical substations can also be divided into public and.
Easy understanding of 3phase transformer connections deltadelta, wyewye, deltawye and wyedelta on photo. In this diagram, a threephase unity pf load resistive load is supplied by two transformers. Thepoten tialcircuitofthewattmetermaynowbeusedasavoltmeterto. However, the line current is also the current in the transformer winding and, if i is the rated current of each of the two transformers and v the rated voltage, then the rated 3phase power is vi. A transformer can not act as a phase changing device and change singlephase into threephase or threephase into single phase. These devices use standard transformer theory with 23 windings one primary with one or two secondary windings with a magnetic connection via an iron core. Basics, maintenance, and diagnostics vii contents continued page 4. The primary and secondary windings of a transformer can be connected in different configuration as shown to meet practically any requirement. A potential transformer must be capable of operating at 110% above rating voltage continuously provided the secondary burden in volt amperes at this voltage does not exceed the thermal rating. This connection is economical for large, low voltage transformers in which insulation problem is not so urgent, because it increases the number of turnsphase.
Medium voltage products technical guide the mvlv transformer. The secondary voltage bears a fixed relation with the. A potential transformer is a conventional transformer having primary and secondary windings. This is a simplest form of potential transformer definition. Voltage transformer is necessary for directional, voltage, distance protection. The behavior of a 3phase transformer bank is analyzed in the same way as for a singlephase unit assume that both the primary and secondary windings are connected in wye configuration consider only one transformer the primary voltage is the linetoneutral voltage, vh1, n the secondary voltage is the linetoneutral voltage. There are three basic styles used to transformer system voltages to control voltages. For the instrument transformers the typical engineering laws that are also used for power transformers can be applied. Figure 31 shows a basic schematic of a single phase traction transformer and its phasor diagram.
The potential transformer reduced the high value of voltage into the small value which can easily be measured by the voltmeter or meter. Instrument transformers is a generic term which refers to either current transformer ct or voltage potential transformer vtpt as compared to power transformers. The company will make final connections to the instrument transformer secondary terminals. Instrument transformers are special types of transformers intended to measure cur rents and voltages.
For a short circuited transformer the equation 1 can be used. Applies to these magnelab ac potential transformers. Compare and contrast the performance of three phase transformer connections. Using potential transformers continental control systems. By using a pt, voltage is reduced that can be safely handled by meter or relay circuits.
The voltage transformer is designed to connect in parallel with the line to transform the line voltage to 115 or 120 volts suitable for the meter or relay. Medium voltage transformers schneider electric global. Instrument transformers convert signal levels from dangerous high voltage or inconvenient high current, or current at high voltage to levels appropriate for metering. The potential transformer may be defined as an instrument transformer used for the transformation of voltage from a higher value to the lower value. Instrument transformers reduce the line current and voltage being provided to the customers load to safe levels for input to solid state meters. Metering connection arrangements for voltage potential transformer starconnection of 3 transformers.
It is used to transforms 2 kv grid voltage into 27. List characteristics on these devices and explain how. Selecting a voltage transformer vt if the ratio, burden, class and optionally voltage factor are selected, the voltage transformer vt or potential transformer pt has been specified basically. Commercially available relays and meters used for protection and metering, are designed for low voltage.
If the hv side of the transformer primary side was connected wyegrounded similar to figure 6 and we had a 3leg core type transformer connection, the primary winding with the lost phase will have an induced voltage equal to the voltage before the open phase condition. This is characteristic of balanced 3phase systems, and is true only. Indentify the schematic symbols of potential and current transformer. Of course additional requirements like type, frequency, environmental conditions should also be specified. The emergency rating of potential transformers is defined at one minute of operation, thus enough time for protective equipment to operate. The current transformer is designed to connect in series with the line to transform the line current to the standard 5 amperes suitable for the meter or relay.
Mar 10, 2016 to start with, both are instrument transformers basically used for measurement and protection purpose in power systems. The electromagnetic potential transformer is a wirewound transformer. Assume idea operation of both cts and pts potential transformer schematic symbol schematic symbols should indicate polarity mark can. If there is an ul tap changer, its wiring must also be checked. Open delta or vconnection of transformer electrical. The transformer does this by linking together two or more electrical circuits using a common oscillating magnetic circuit which is produced by the transformer itself. These can be single or three phase voltage transformers available for different range of operating voltages that are used for outdoor relaying and metering applications.
Here we will cover six important aspects of using instrument transformer in the power system. Potential transformer voltage transformer is used for protection and measurement. Three phase transformer connections phasor diagrams. For example, the potential transformer mentioned above having a rating of 480. Potential transformer pt definition the potential transformer may be defined as an instrument transformer used for the transformation of voltage from a higher value to the lower value.
Among the materials consulted while preparing this book are. Banked two or more single phase transformers connected together to supply a three phase load. Pdf conductive disturbances in the supplying voltage may affect the root mean square voltage and shape of the voltage curve on the mains which reflect. They are designed for connection linetoline or linetoneutral in the same manner as ordinary voltmeters. Adding potential transformers has the effect of reducing the measured line voltage by the pt ratio lets say 35.
Cts current transformers pts potential transformers. If the transformer leakage impedances are neglected, and their ratio is a, then the secondary voltages are but from kirchhoffs law from which showing that the secondary voltages v ab, v bc, and v ca are equal in magnitude and displaced from each other by an angle of 120. These potential transformers will be used as busbar p. Acme transformers can be used at frequencies above 60 hz up through 400 hz with no limitations provided nameplate voltages are not exceeded. The wyeconnected secondary allows singlephase load to be distributed among the three phases to neutral instead of being placed all on one winding as with a fourwire delta secondary.
Threephase transformer connections there are various methods available for transforming 3phase voltages to higher or lower 3phase voltages i. Standard current transformer multiratio taps 214 burden standards 214 5 kv 36 kv indoor voltage transformers primary current class abb type geiti equivalent abb product bulletin page 2400 to 4800 5 kv indoor viy60 ptw3160 and ptw3260 1vap429511db 148149 2400 to 72007200 8. Potential transformers pts are necessary to a power system for metering and protective relaying to convert higher system voltages to lower control voltages that are more practical from an equipment, operation, and safety perspective. Any single phase transformer can be used on a three phase source by connecting the. To do so can result in very high voltages in the secondary systems. Capacitor voltage transformer cvt or capacitor coupled voltage transformer ccvt is a switchgear device used to convert high transmission class voltage into easily measurable values, which are used for metering, protection, and control of high voltage systems additionally, a cvtccvt used as coupling capacitors for coupling highfrequency power line carrier signals to the transmission line. Mutual induction is the process by which a coil of wire magnetically. Adjustment capacitors are provided in the device for connecting in parallel with the burden on one secondary winding to correct the totalburden power factor to. Explain and interpret information found on transformer name plates. V l is the linetoline voltage, and v p is the phasetoneutral voltage. Maximum allowed torques for screw connections of current transformers maximum allowed torque for screw connection of voltage transformer is 20 nm. A comparative study of different transformer connections for. They are designed for connection linetoline or linetoneutral.
The figure below shows the connections for testing a potential transformer using a resistance potential divider. The potential transformer is mainly classified into two types, i. The singlephase distribution transformer consists of a primary winding and a secondary winding wound on a laminated steel core. Instrument transformer theory and testing steve hudson, pe. Dec 30, 2018 potential transformer or voltage transformer gets used in electrical power system for stepping down the system voltage to a safe value which can be fed to low ratings meters and relays. Transformer protection application guide this guide focuses primarily on application of protective relays for the protection of power transformers, with an emphasis on the most prevalent protection schemes and transformers. However, 60 hz transformers will have less voltage regulation at 400 hz than 60 hz. Some of the most commonly occurring failures of the transformer and their causes are listed below. Generally, the primary winding of a transformer is connected to the input voltage supply and converts or. Threephase voltage and current ratios for rectifier circuits.
Identify transformer polarity using dot and conventional labeling. Line to ground voltage monitoring on ungrounded and. Up to 33kv, these are of electromagnetic type single and three phase voltage transformers. Potential transformer accuracy voltage disturbance. Working of potential transformer the electrical portal. In the case of three phase transformer windings, three forms of connection are possible. Metering connection arrangements for voltage potential transformer star connection of 3 transformers. To make the transformer connections compatible with threephase supplies we need to connect them together in a particular way to form a three phase transformer configuration. Transformer rfq form to request a specific part to meet your requirements. But voltage transformers can also be constructed for connection to not only one single phase, but for twophases, threephases, sixphases and even elaborate.
959 1039 319 210 119 493 921 788 1188 849 628 1558 978 340 1121 553 1653 767 1318 76 226 162 485 751 815 364 1572 141 1288 739 138 1083 80 964 1043 814 1025 527 1193 1326 952 68 927 1096 1028 236 345 795 1016